Water Heater Size Calculator

What size water heater do you need? Estimate your peak-hour hot water demand for a tank (first-hour rating) and the flow and power for a tankless heater.

≈ 10 gal each
≈ 20 gal each
≈ 6 gal
≈ 7 gal (hot/warm)
≈ 2–5 gal each

Results

Peak-hour hot water demand
45 gal (170 L)
Tank: minimum first-hour rating (FHR)
45 gal
Typical tank size for your household
40–50 gal
Tankless: flow needed
5.5 gpm at a 70 °F rise
Tankless gas: output
193k BTU/h
Tankless electric
56.4 kW (≈ 235 A at 240 V)
⚠️ Whole-house electric tankless heaters this large often need a 200 A service and several dedicated circuits — have an electrician check your panel first.
💡 Look for the first-hour rating (FHR) on the EnergyGuide label — it matters more than tank size. Gallons per use follow the U.S. Department of Energy sizing worksheet.

How to do it

Difficulty: AdvancedTime: Half a day (replacing like-for-like)

Tools you’ll need

  • Pipe wrenches / adjustable wrenches
  • Tubing cutter
  • Garden hose (to drain)
  • Voltage tester (electric)
  • Leak-detection solution (gas)
  • Appliance dolly

Steps

  1. Choose a heater whose first-hour rating (tank) or gpm at your temperature rise (tankless) meets the numbers above.
  2. Turn off power or gas and the cold supply, then drain the old tank through the drain valve.
  3. Disconnect water, gas/power and venting, and remove the old unit.
  4. Set the new heater (drain pan and expansion tank where required), connect water lines with dielectric unions and a new T&P relief line.
  5. Reconnect gas and venting (or wiring), fill the tank completely before turning on power or gas, then check for leaks.

Common mistakes

  • Turning on an electric heater before it’s full — burns out the element.
  • Missing or capped T&P relief valve discharge line.
👷 When to call a pro: Gas lines, venting and new electrical circuits are high-risk — most areas require a licensed plumber or permit for water-heater replacement.

Formula

Peak-hour demand = Σ (uses in the busiest hour × gallons per use); tankless BTU/h = gpm × 500 × temperature rise (°F)

More DIY Projects calculators